BASIC INFO
BW Technologies Hydrogen sulfide Detectors GasAlert Extreme 0-500 ppm H2S Detector GAXT-H-2-DL
GasAlert Extreme
Designed with durability and comfort in mind, this gas detector monitors for any single gas hazard within its wide range of available toxic gas models.
Features & Benefits
Equipped with internal vibrating alarm for high noise areas
Secure and accurate history with datalogging option
Multi-language support in English, French, German, Spanish, and Portuguese
Quick Specs
Size:1.1 x 2.0 x 3.75 in./ 2.8 x 5.0 x 9.5 cm
Weight:2.9 oz./ 82 g
Alarms: visual, vibrating, audible (95dB)- Low, High, TWA and STEL
Tests: Sensor integrity, circuitry, battery and audible/visual alarms on activation, battery (continuous)
Pump: Compatible with the Sampler motorized pump
Typical battery life:1.5 year battery life (typical) with replaceable 3V battery
Product Overview
With easy on/off operation, this single gas detector offers extended longevity with a two year field-replaceable battery and sensor. Calibration is a simple automatic procedure and is compatible with BW Technologies by Honeywell's MicroDock II automatic test and calibration system. A wide range of user options, multi-language display and datalogging functionality make the GasAlert Extreme an ideal solution for many applications.
Additional GasAlert Extreme features:
Tamper-proof settings with passcode protection
Continuous LCD shows real-time gas concentration
Compact and lightweight design makes it comfortable to wear
Water-resistant
Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
Concussion-Proof Boot
GA-BALERT
Heavy duty protection for extreme conditions. The concussion-proof boot slips easily and securely onto the detector for additional protection in extreme conditions. Equipped with a rugged stainless steel alligator clip, the external rubber boot also helps keep the detector clean.
IR Data Link
GA-USB2
With the IR DataLink USB adaptor and IR DataLink software (included) by BW Technologies, a user can easily download event log information from the GasAlertClip Extreme gas monitors or download data log information from the GasAlert Extreme (data logging model only).
GasAlert Extreme Dock Station
DOCK2-2-1D-00-G
The most cost effective way to manage the calibration and bump testing of BW's portable gas detectors is through the MicroDock II automated test and calibration system. Fully portable and easily expandable, the MicroDock II requires no computer and provides simultaneous management of up to six modules.
GAXT-A-DL
GAXT-A-DL-B
GAXT-A2-DL
GAXT-A2-DL-B
GAXT-M-DL
GAXT-M-DL-B
GAXT-M2-DL
GAXT-M2-DL-B
GAXT-C-DL
GAXT-C-DL-B
GAXT-V-DL
GAXT-V-DL-B
GAXT-E-DL
GAXT-E-DL-B
GAXT-Z-DL
GAXT-Z-DL-B
GAXT-H-DL
GAXT-H-DL-B
GAXT-H-2-DL
GAXT-H-2-DL-B
GAXT-N-DL
GAXT-N-DL-B
GAXT-D-DL
GAXT-D-DL-B
GAXT-X-DL-2
GAXT-X-DL-B-2
GAXT-G-DL
GAXT-G-DL-B
GAXT-P-DL
GAXT-P-DL-B
GAXT-S-DL